EPA/ANSI-AARST

United States

Reference Level: 148 Bq/m³

Overview

Scope: All buildings
Legal Reference: EPA 402/K-12/002; ANSI/AARST MAH-2023 (homes), MA-MFLB-2023 (buildings), MS-QA-2023

Measurement Protocol

Duration: 0.07-3 months
Detector Type: Activated charcoal, electrets, track-etch, continuous monitors
Measurement Season: Short test: 2-90 days closed-house; Long test: >90 days

Short-Term Test Option

2-90 days short-term test available (12h closed-house conditions)

Confirmation test required if ≥148 Bq/m³

Laboratory Requirements

Accreditation: Devices listed by NRPP (National Radon Proficiency Program) or NRSB

QA/QC Requirements

  • • 10% duplicate samples
  • • 5% blank samples
  • • 3% spike samples

Alternative Units

Action Level: 4 pCi/L (≈148 Bq/m³)

1 pCi/L ≈ 37 Bq/m³