Radon in workplaces in Ireland
Requirements that apply to workplaces in Ireland. They do not apply in other countries.
What the employer must do
Legal reference level 300 Bq/m³ for workplaces (reduced from 400 Bq/m³ in 2019, IRR19). Mandatory measurement in high radon areas.
Measurement protocol: EPA Protocol 2019
Compliance: EPA Protocol for Measurement of Radon in Workplaces (2019)
- Reference level
- 300 Bq/m³
- Minimum duration
- ≥ 3 months
- Detector type
- Passive track-etch detectors (CR-39, ≥3 months)
- Measurement period
- 3-12 months with seasonal adjustment factors
- Laboratory
- EPA registered radon measurement service
- Legal basis
- S.I. No. 30/2019 — EPA Protocol May 2019
Official sources
Informative summary. The official text of the regulation prevails. Check the source before taking a compliance decision.