Monitoring & Diagnostic Equipment
Continuous radon monitors, short-term and long-term test kits, differential pressure monitors, U-tube manometers, airflow and pressure measurement instruments, and system performance alarms. Essential tools for system design, post-mitigation verification, and ongoing performance monitoring.
Application
Intervention Type
Monitoring and diagnostic equipment for pre-installation testing, post-mitigation verification, and ongoing system performance monitoring. From continuous radon monitors to differential pressure gauges and fan failure alarms.
Browse professional-grade measurement tools, test kits, pressure monitors, and system performance alarms from verified manufacturers and providers.
Product Types
Consumer-Grade Continuous Radon Monitors
Electronic devices with Bluetooth/WiFi for homeowner monitoring, not compliance reporting
Popular Brands:
- •Bluetooth/WiFi connectivity
- •Real-time or hourly readings
Professional-Grade Continuous Radon Monitors
Reference standard monitors with annual recalibration for compliance reporting
Popular Brands:
- •±3% accuracy (AlphaGUARD)
- •Annual recalibration to national standards
Activated Charcoal Canisters
2-7 day screening tests using gamma emission counting
- •2-7 day screening
- •$20-40 cost
Alpha-Track Detectors
90-day to 1-year integrating detectors, gold standard for annual average
- •90-day to 1-year integration
- •7-30 Bq/m³ detection limit
Electret Ion Chambers
Short or long-term detectors using charged Teflon disc discharge
- •2-15 days (short-term) or 3-12 months (long-term)
- •Charged Teflon disc
U-Tube Manometers
Simple, reliable differential pressure monitors with colored fluid column
- •0.1" w.c. (25 Pa) resolution
- •0-6" w.c. (0-1,500 Pa) range
Digital Differential Pressure Gauges
Electronic sensors with higher resolution and data logging
Popular Brands:
- •0.01" to 0.001" w.c. resolution
- •Data logging capability
Vane Anemometers
Rotating vane measures air velocity in ducts and grilles
- •Rotating vane design
- •Duct and grille measurement
Thermal Anemometers (Hot-Wire)
Heated sensor for low-velocity airflow measurement
- •More sensitive at low velocities
- •Heated sensor design
Flow Hoods (Balometers)
Fabric hood capturing total airflow from diffusers or grilles
- •Direct CFM or m³/h reading
- •Fabric hood with integrated fan
Pressure-Activated Fan Failure Alarms
Monitor sub-slab pressure and alert on fan failure or blockage
- •Monitors sub-slab pressure
- •Alarms when pressure rises
Current-Sensing Fan Failure Alarms
Detect fan motor electrical current for failure detection
- •Split-core current transformer
- •Adjustable trip threshold
Radon Level Alarms
Continuous monitors with programmable thresholds alerting occupants
- •Programmable alarm thresholds
- •Typical setpoint 200 Bq/m³ or 5.4 pCi/L